Calibration of cathode ray oscilloscope - Project Ideas | Grossarchive.com

Explore Project Topics on: Calibration of cathode ray oscilloscope

Related Works

ABSTRACT The cathode ray Oscilloscope plays a very important role in the laboratories, for instance it is used to measure frequency and voltage of a signal it is equally used for study current fluctuation in electric power supply the cathode ray oscilloscope is made up of... Continue Reading
ABSTRACT   The cathode ray Oscilloscope plays a very important role in the laboratories, for instance it is used to measure frequency and voltage of a signal it is equally used for study current fluctuation in electric power supply the cathode ray oscilloscope is made up of three major part, they are the cathode ray tube, which is the major... Continue Reading
ABSTRACT The cathode ray Oscilloscope plays a very important role in the laboratories, for instance it is used to measure frequency and voltage of a signal it is equally used for study current fluctuation in electric power supply the cathode ray oscilloscope is made up of three major part, they are the cathode ray tube, which is the major integral... Continue Reading
Electromagnetic Distance Measurement (EDM) equipment is calibrated on a base to determine  instrument constants and errors. A series of measurements on a base can also be used to check  the performance and reliability of the instrument over time and to assess its precision against  the manufacturer's specifications. This research work, the... Continue Reading
Electromagnetic Distance Measurement (EDM) equipment is calibrated on a base to determine  instrument constants and errors. A series of measurements on a base can also be used to check  the performance and reliability of the instrument over time and to assess its precision against  the manufacturer's specifications. This research work, the... Continue Reading
ABSTRACT A Linear  Variable Differential Transformer (LVDT) was constructed having a primary winding of 245 turns and two secondary windings of 100 turns each. The device was calibrated with a graduated cylindrical rod. The graduated rod when inserted between the hollow tube which has the windings gave output voltages of ±0.046V, ±0.51V,... Continue Reading
ABSTRACT A Linear  Variable Differential Transformer (LVDT) was constructed having a primary winding of 245 turns and two secondary windings of 100 turns each. The device was calibrated with a graduated cylindrical rod. The graduated rod when inserted between the hollow tube which has the windings gave output voltages of ±0.046V, ±0.51V,... Continue Reading
Crude oil viscosity is an important parameter which is considered in both porous media and in pipeline channels. Estimating oil viscosity at various operating conditions of pressure and temperature is of great value to petroleum engineers. In petroleum and reservoir engineering, we are often faced with the analysis of processes which involve... Continue Reading
Crude oil viscosity is an important parameter which is considered in both porous media and in pipeline channels. Estimating oil viscosity at various operating conditions of pressure and temperature is of great value to petroleum engineers. In petroleum and reservoir engineering, we are often faced with the analysis of processes which involve... Continue Reading
ABSTRACT This research work presents the results of the thermal power calibration of Nigeria Research Reactor-1 (NIRR-1), a low power Miniature Neutron Source Reactor (MNSR), using calorimetric and heat balance methods. The calibration was performed at two different power levels: half power (15kW) and full power (30kW). The calorimetric method... Continue Reading
ABSTRACT This research work presents the results of the thermal power calibration of Nigeria Research Reactor-1 (NIRR-1), a low power Miniature Neutron Source Reactor (MNSR), using calorimetric and heat balance methods. The calibration was performed at... Continue Reading
ABSTRACT An important aspect of general quality assurance program for brachytherapy dosimetry is source calibration. Vendors assign large uncertainties of up to ±10 % for the stated source calibrated values. It is thus important to check the vendor stated calibration. There are three main methods of calibrating brachytherapy sources and they are... Continue Reading